MANUAL
EVT-PB1-H05Q
Video, Power and Data Balun
with Voltage Booster
The ENFORCER EVT-PB1-H05Q Video, Power and Data (VPD) Balun with Voltage Booster
combines the flexibility of a VPD Balun with the ability to boost insufficient voltage for use in CCTV
applications. Boosted DC power is regulated to provide stable power suitable for voltage sensitive
Transmit video up to 2000’ over Cat5
Selectable 12/24VDC output via jumper
Regulated and filtered output.
Dual-colored LED power output indicator:
Red: 12VDC
Blue: 24VDC
Output current protection – 500mA
Small size for easy installation.
Green power input LED indicator.
Built-in overload and short-circuit protection.
NOTE: Products with a model number that ends with “Q” or have a round green “Q” sticker represent RoHs compliant products.
ENFORCER Video, Power and Data Balun with Voltage Booster
Installation:
1. Run UTP cable to the camera where the VPD balun is being installed.
2. Remove the cover by simultaneously pressing down on the top cover, and lifting up on the side
mounting tabs. This will release the tight seal between the top and bottom covers.
3. Set the desired output voltage using the selection jumper according to table 1 below.
4. Connect output wires from the power supply to the power input terminal blocks on the balun.
Observe correct polarity
5. Apply power and use table 2 and 3 below to check the status of the input and output voltages.
NOTE: To avoid potential damage, use a voltage meter to ensure proper voltage is
present at the input and output terminal blocks. Observe correct polarity.
6. Connect the camera to the DC plug on the balun. If the output voltage is too low, then turn the
rotary knob clockwise to increase the voltage or counter-clockwise to decrease the voltage.
7. Connect the video input male BNC input in from the VPD Balun to the camera.
8. If using a RS-485 controlled camera, connect the data in wires to the camera.
9. Using the input terminal blocks, connect data and video wires to the balun according to Figure 1.
IMPORTANT: Correct polarity must be observed on all connections.
10. Replace the cover on the voltage booster.
Table 1: Adjustable Output Voltage
Input Voltage
7~12VDC
12~24VDC
Output Voltage Adjustable voltage range Jumper Settings
12VDC
24VDC
12.5 ± 5%VDC
24.0 ± 10%VDC
Table 2: Wiring Distance 12 VDC Voltage Drop
Table 3: LED Indicators
1 Pair
90'
45'
30'
20'
2 Pairs 3 Pairs
LED colors
Green
Red
Status
24 AWG Wire
250mA
500mA
750mA
1A
Power is connected
Output is 12VDC
Output is 24VDC
220'
110'
75'
550'
285'
190'
140'
Blue
55'
NOTE: Chart is based on standard Cat5 24AWG wire and an allowable 10% voltage drop.
Figure 1: Sample Application
NOTE: To avoid potential damage, use a voltage meter to
ensure proper voltage is present at the input and output
terminal blocks. Observe correct polarity.
Power
Supply
VDC out
Video in
Data out
SECO-LARM
Video Balun
Cat5 cable
DVR
PTZ
Controller
Also Available from SECO-LARM:
Passive & Active
BNC-to-VGA
Converter
VPD Balun with
Voltage Booster
Passive VGA Balun
Video Baluns
EVT-SBP-GQ
EVT-PB1Q
VC-1BAQ
EVT-PB1-H05Q
(shown)
SECO-LARM U.S.A., Inc
3
ENFORCER Video, Power and Data Balun with Voltage Booster
Voltage Booster Efficiency Rate:
The EVT-PB1-H05Q has a power efficiency rating of 85%. Under typical conditions, the booster will provide sufficient power to
compensate for long cable runs. The following formulas can be used to determine if enough power is present at the power
input of the voltage booster:
1. Calculate the amount of power measured in Watts:
Voltage x Current = Power
2. For example, if the voltage is 12VDC, and the current is 750mA:
12VDC x .75 = 9 Watts
3. Then calculate the amount of power using the voltage booster with the following formula:
Power Input x Efficiency Rate = Power Output.
4. Using the 9 Watts in the previous example, calculate power input of the booster:
9 Watts x .85 = 7.65 Watts
5. After the power has been calculated, the output current is calculated from the following formula:
Power / Voltage = Current
6. Using the example of 9 watts present at the power input, and 7.65 Watts at the power output:
7.65 Watts / 12VDC = 640mA of available current
Use Table 3 to determine if additional pairs of Cat5 cable will be needed to transmit power.
Troubleshooting:
Output voltage is low/high
Check voltage jumper settings
Check output voltage adjustment.
Check input voltage to make sure it meets the input
requirements
Green input LED not on
Check input power connections with multimeter to verify
correct input voltage
Blue/red output LED not on
Check to see if the load exceeds the maximum limit
Temporarily disconnect power input and output wires for 30
seconds before connecting
WARRANTY This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for a period of one (1) year from the date of sale to the original consumer customer. SECO-LARM’s obligation is
limited to the repair or replacement of any defective part if the unit is returned, transportation prepaid, to SECO-LARM.
This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse, neglect,
repair, or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-LARM determines
that such equipment is not operating properly as a result of causes other than defects in material and workmanship.
The sole obligation of SECO-LARM, and the purchaser’s exclusive remedy, shall be limited to replacement or repair only,
at SECO-LARM’s option. In no event shall SECO-LARM be liable for any special, collateral, incidental, or consequential
personal or property damages of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication. However, the
SECO-LARM policy is one of continual development and improvement. For this reason, SECO-LARM reserves the right
to change specifications without notice. SECO-LARM is also not responsible for misprints or typographical errors.
Copyright © 2008 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or copied, in
whole or in part, without the written permission of SECO-LARM.
SECO-LARM® U.S.A., Inc.
PITSW4
16842 Millikan Avenue, Irvine, CA 92606
E-mail: sales@seco-larm.com
Tel: 800-662-0800 / 949-261-2999 Fax: 949-261-7326
mi-EVT-PB1-H05Q.docx
4
SECO-LARM U.S.A., Inc.
|
PYLE Audio Speaker PLMR44 User Guide
Radio Shack Cordless Telephone ET 557 User Guide
Remington Hair Dryer DC 1625 User Guide
Renesas Computer Hardware HS7046ECH61H User Guide
Ricoh PDAs Smartphones EL 6991 User Guide
Roland Drums TR 808 User Guide
Rosewill Network Card N600PCE User Guide
Samsung Bluetooth Headset B1914B1914 User Guide
Scientific Atlanta DVR 8640HDC User Guide
Seagate Speaker ST3500641NS User Guide